SW200-279 36-48 V DC Albright güç Kontaktörü
Click image for Gallery
APPLICATION | INTERRUPTED | UNINTERRUPTED |
Thermal Current Rating | 250A | 400A |
Intermittent Current Rating: | ||
30% Duty | 455A | 730A |
40% Duty | 395A | 630A |
50% Duty | 355A | 565A |
60% Duty | 325A | 515A |
70% Duty | 300A | 480A |
Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant:(In accordance with UL583*) | ||
Blowouts | 1500A at 96V D.C. | |
No Blowouts | 1500A at 48V D.C. | |
Rated Fault Current Breaking Capacity (Icn) Resistive Load:(In accordance with UL508*) | ||
Blowouts | 600A at 96V D.C. | |
No Blowouts | 600A at 60V D.C. | |
Maximum Recommended Contact Voltages | ||
Blowouts | 96V | 96V |
No Blowouts | 48V | 60V |
Typical Voltage Drop per pole across New Contacts at 250A | 40mV | |
Mechanical M.T.B.F | >5000000 Operations | |
Coil Voltage Available (Us) (Rectifier board required for A.C.) | 6 - 240V |